Backup & Disaster Recovery appliance cannot connect to VMware ESXi 6.7

On this page

Issue

Attempt to connect Backup & Disaster Recovery appliance to VMware ESXi 6.7 fails.

Issue description

ESXi 6.7 requires TLS 1.2 connection unless otherwise configured.

Users who already updated their infrastructure to ESXi 6.7 can temporary enable TLS 1 protocol by modifying the ESXiVPsDisabledProtocols key in HostManageAdvanced Settings in the vSphere web client. ESXi host reboot is required.

Known impacts
ESXi 6.7 will show incorrect supported hardware version in the appliance Management Console: 4 instead 14.

An attempt to restore VM with hardware 14 back to ESXi 6.7 will display a warning that can be safely ignored.

Affected versions:

  • ESXi 6.7

  • Appliances with firmware version 6.15 and earlier